Direct Detection of Chloride & Sulfate
The 3000CS provides a method for direct, online detection of corrosive ions without measurement interference from other ions or common additives.
Rapid Monitoring to Prevent Corrosion
Measurement cycles every 45 minutes ensure you can quickly react to chloride and sulfate excursions to prevent corrosive conditions from occurring.
Reduced Monitoring Effort and Costs
Typical chloride and sulfate monitoring requires expensive resources and lab work. The 3000CS eliminates the need for costly offline tests.
Material No.: 58044001
Chloride Measurement Range | 0-300 ppb |
Chloride Limit of Detection | 0.5 ppb |
Chloride Measurement Accuracy | ±5% of reading or ± 0.5 ppb whichever is greater |
Sulfate Measurement Range | 0-300 ppb |
Sulfate Limit of Detection | 1 ppb |
Sulfate Measurement Accuracy | ±10% of reading or ±1 ppb whichever is greater |
Measurement Cycle Time | 45 min typical, programmable between 15 minutes and 1 hour |
Sample Flow rate | 25-50 mL/min |
Sample Temperature | 10-45°C (50-113°F) |
Sample Pressure | 0.3-7 bar (5-100 psig) |
Grab Sample Measurement | Included 100 mL capacity |
Power Supply | 100-240 VAC, 50-60 Hz, 100 W typical |
Dimensions (HxWxD) | 927x508x305 mm (36.5"x20.9"x12") |
Weight | 44 kg (97 lbs) |
Ambient Operating Temperature | 10-35°C (50-95°F) |
Humidity | 10-70% non-condensing |
Ratings/Approvals | CE / cULus |
Process Connection | Sample Inlet: 1/4" or 6 mm OD tube SS compressin fitting Drain Hose: 19x25.4 mm (3/4 x 1") 2 m (6 ft) length included |
Operator Interface | Color touchscreen Simultaneous display of ion concentrations and analyzer status |
Analog Output | 22mA alarm, 500 ohm max load, not for use with externally powered circuit |
Analog Output Scaling | Linear, bi-linear, logarithmic (1,2,3,4 decades), auto ranging |
Measurement Parameter | Chloride and sulfate |
Relay Contacts | Mechanical rated at 250 VAC, 3 Amps (Relay 1 NC, Relay 2 to 4 NO), 4-SPDT Type Reed 250 VAC or DC, 0.5 Amps (Relay 5 to 8) |
Analog Output Accuracy | ±0.05 mA |
Model Family | 3000CS |
EnclosureType | Full |
Built-in sequencer | No |
Versatile for Critical Applications
The 3000CS is designed for measurement in a range of power plant water applications, including steam quality monitoring at the turbine inlet, condensate monitoring at the condensate polisher, boiler feedwater monitoring, and makeup water quality monitoring.
Intuitive Interface with Data Trends
This online chloride and sulfate analyzer uses the METTLER TOLEDO M800 transmitter with an intuitive touch screen interface to easily monitor cycle chemistry. It offers unique information such as trendlines for each measurement.
Easy Integration for Data Management
The 3000CS has an analog output for keeping a record of the chloride and sulfate contamination levels in your data acquisition software. This helps ensure that you stay within the specifications of your turbine warranty and helps you identify the causes of contamination.
Durable Enclosure for a Long Lifetime
A full enclosure protects the reagent containers and components of the 3000CS from harsh environmental conditions, ensuring a measurement unaffected by outside influences. The 3000CS operates in humidities from 10% to 70% (non-condensing).